Hyperaccuracy Three-Dimensional Model and Augmented Reality/Mixed Reality for Robot-Assisted Retroperitoneal Lymph Node Dissection in Testicular Cancer

June 16, 2026

This case report evaluates the feasibility of Avatar Medical's hyperaccuracy 3D (HA3D) modeling with augmented reality in robot-assisted retroperitoneal lymph node dissection (R-RPLND) for testicular cancer. Built from contrast-enhanced CT and integrated into both preoperative planning and intraoperative AR navigation, the model enabled precise identification of a critical renal arterial branch adjacent to the tumor, supporting a dissection completed in 76 minutes with minimal blood loss and no complications. Nine-month follow-up showed no recurrence, demonstrating how HA3D visualization can enhance precision and safety in complex robotic urologic surgery.